Witam! Mam do sprzedania 24-portowy gigabitowy switch Cisco 3750 (WS-C3750G-24TS) z dodatkowymi czterema gigabitowymi portami SFP. Switch jest używany i posiada drobne rysy od szafy montażowej. Jest w pełni sprawny.
Log z uruchomienia oraz z sh ver:
Base ethernet MAC Address: 00:11:bb:f9:8a:00 Xmodem file system is available. The password-recovery mechanism is enabled. Initializing Flash... flashfs[0]: 451 files, 7 directories flashfs[0]: 0 orphaned files, 0 orphaned directories flashfs[0]: Total bytes: 15[zasłonięte]976 flashfs[0]: Bytes used:[zasłonięte]93987 flashfs[0]: Bytes available:[zasłonięte]66001 flashfs[0]: flashfs fsck took 9 seconds. ...done Initializing Flash. Boot Sector Filesystem (bs) installed, fsid: 3 done. Loading "flash:c3750-ipbasek9-mz.122-25.SEE4/c3750-ipbasek9-mz.122-25.SEE4.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ File "flash:c3750-ipbasek9-mz.122-25.SEE4/c3750-ipbasek9-mz.122-25.SEE4.bin" uncompressed and installed, entry point: 0x3000 executing... Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Commercial Computer Software - Restricted Rights clause at FAR sec. 52.227-19 and subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS sec. 252.[zasłonięte]227-70. cisco Systems, Inc. 170 West Tasman Drive San Jose, California 95[zasłonięte]-1706 Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEE4, RELEASE SOFTWARE (fc1) Copyright (c) 1[zasłonięte]986-20 by Cisco Systems, Inc. Compiled Mon 16-Jul-07 03:24 by myl Image text-base: 0x00[zasłonięte]000, data-base: 0x01[zasłonięte]000 Initializing flashfs... flashfs[1]: 451 files, 7 directories flashfs[1]: 0 orphaned files, 0 orphaned directories flashfs[1]: Total bytes: 15[zasłonięte]976 flashfs[1]: Bytes used:[zasłonięte]93987 flashfs[1]: Bytes available:[zasłonięte]66001 flashfs[1]: flashfs fsck took 1 seconds. flashfs[1]: Initialization complete....done Initializing flashfs. Checking for Bootloader upgrade.. not needed POST: CPU MIC register Tests : Begin POST: CPU MIC register Tests : End, Status Passed POST: PortASIC Memory Tests : Begin POST: PortASIC Memory Tests : End, Status Passed POST: CPU MIC PortASIC interface Loopback Tests : Begin POST: CPU MIC PortASIC interface Loopback Tests : End, Status Passed POST: PortASIC RingLoopback Tests : Begin POST: PortASIC RingLoopback Tests : End, Status Passed Waiting for Stack Master Election (around 30 seconds)... POST: PortASIC CAM Subsystem Tests : Begin POST: PortASIC CAM Subsystem Tests : End, Status Passed POST: No Cable found on stack port 1 POST: No Cable found on stack port 2 POST: PortASIC Stack Port Loopback Tests : Begin POST: PortASIC Stack Port Loopback Tests : End, Status Passed POST: PortASIC Port Loopback Tests : Begin POST: PortASIC Port Loopback Tests : End, Status Passed Election Complete Switch 1 booting as Master Waiting for Port download...Complete This product contains cryptographic features and is subject to United States and local country laws governing import, export, transfer and use. Delivery of Cisco cryptographic products does not imply third-party authority to import, export, distribute or use encryption. Importers, exporters, distributors and users are responsible for compliance with U.S. and local country laws. By using this product you agree to comply with applicable laws and regulations. If you are unable to comply with U.S. and local laws, return this product immediately. A summary of U.S. laws governing Cisco cryptographic products may be found at: http://www.cisco.com/wwl/export/crypto/tool/stqrg.html If you require further assistance please contact us by sending email to [zasłonięte]@cisco.com. cisco WS-C3750G-24TS (PowerPC405) processor (revision F0) with 118784K/12280K bytes of memory. Processor board ID CAT0833X2MZ Last reset from power-on 1 Virtual Ethernet interface 28 Gigabit Ethernet interfaces The password-recovery mechanism is enabled. 512K bytes of flash-simulated non-volatile configuration memory. Base ethernet MAC Address : 00:11:BB:F9:8A:00 Motherboard assembly number : 73-7058-10 Power supply part number : 341-[zasłonięte] 0045 Motherboard serial number : CAT083104YR Power supply serial number : PHI[zasłonięte]08180M Model revision number : F0 Motherboard revision number : A0 Model number : WS-C3750G-24TS-S System serial number : CAT0833X2MZ Hardware Board Revision Number : 0x09 Switch Ports Model SW Version SW Image ------ ----- ----- ---------- ---------- * 1 28 WS-C3750G-24TS 12.2(25)SEE4 C3750-IPBASEK9-M Failed to generate persistent self-signed certificate. Secure server will use temporary self-signed certificate. Press RETURN to get started! 00:01:23: %STACKMGR-4-SWITCH_ADDED: Switch 1 has been ADDED to the stack 00:01:24: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down 00:01:26: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan 00:01:28: %SYS-5-CONFIG_I: Configured from memory by console 00:01:28: %STACKMGR-5-SWITCH_READY: Switch 1 is READY 00:01:28: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN 00:01:28: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN 00:01:28: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY 00:01:28: %SYS-5-RESTART: System restarted -- Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEE4, RELEASE SOFTWARE (fc1) Copyright (c) 1[zasłonięte]986-20 by Cisco Systems, Inc. Compiled Mon 16-Jul-07 03:24 by myl Switch>en Switch#sh ver Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEE4, RELEASE SOFTWARE (fc1) Copyright (c) 1[zasłonięte]986-20 by Cisco Systems, Inc. Compiled Mon 16-Jul-07 03:24 by myl Image text-base: 0x00[zasłonięte]000, data-base: 0x01[zasłonięte]000 ROM: Bootstrap program is C3750 boot loader BOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.1(14r)EA1a, RELEASE SOFTWARE (fc1) Switch uptime is 3 minutes System returned to ROM by power-on System image file is "flash:c3750-ipbasek9-mz.122-25.SEE4/c3750-ipbasek9-mz.122-25.SEE4.bin" This product contains cryptographic features and is subject to United States and local country laws governing import, export, transfer and use. Delivery of Cisco cryptographic products does not imply third-party authority to import, export, distribute or use encryption. Importers, exporters, distributors and users are responsible for compliance with U.S. and local country laws. By using this product you agree to comply with applicable laws and regulations. If you are unable to comply with U.S. and local laws, return this product immediately. A summary of U.S. laws governing Cisco cryptographic products may be found at: http://www.cisco.com/wwl/export/crypto/tool/stqrg.html If you require further assistance please contact us by sending email to [zasłonięte]@cisco.com. cisco WS-C3750G-24TS (PowerPC405) processor (revision F0) with 118784K/12280K bytes of memory. Processor board ID CAT0833X2MZ Last reset from power-on 1 Virtual Ethernet interface 28 Gigabit Ethernet interfaces The password-recovery mechanism is enabled. 512K bytes of flash-simulated non-volatile configuration memory. Base ethernet MAC Address : 00:11:BB:F9:8A:00 Motherboard assembly number : 73-7058-10 Power supply part number : 341-[zasłonięte] 0045 Motherboard serial number : CAT083104YR Power supply serial number : PHI[zasłonięte]08180M Model revision number : F0 Motherboard revision number : A0 Model number : WS-C3750G-24TS-S System serial number : CAT0833X2MZ Hardware Board Revision Number : 0x09 Switch Ports Model SW Version SW Image ------ ----- ----- ---------- ---------- * 1 28 WS-C3750G-24TS 12.2(25)SEE4 C3750-IPBASEK9-M Configuration register is 0xF
Jeśli odbiorca sobie zażyczy to mogę wysłać switch zgodnie z cennikiem firmy kurierskiej, ale nie biorę na siebie odpowiedzialności za dostawę.
Daję tygodniową gwarancję rozruchową.