Technical specifications "HEATING PUMP"
|
|
AOYZ 14 LBL
|
AOYZ 18 LBL
|
AOYZ 24 LBT |
Cooling capacity (min. - nom. - max.)*
|
kW
|
0,9 - 4,2 - 5,3 |
0,9 - 5,2 - 5,9 |
0,9 - 7,1 - 8,00
|
Heating capacity (min. - nom. - max.)*
|
kW |
0,9 - 6,0 - 9,1 |
0,9 - 6,7 - 9,7 |
0,9 - 8,5 - 11,0
|
Refrigerant
|
|
R410a
|
R410a |
R410a |
Maximum air flow (C/H)
|
m³/h |
1910/1910
|
1910/1910
|
3600/3320
|
Connection voltage
|
V |
230/1 |
230/1
|
230/1 |
Absorbed current in cooling (Nominal)
|
A |
4,50 |
6,90 |
9,70 |
Absorbed current in heating (Nominal)
|
A
|
5,90
|
7,20
|
9,80 |
Absorbed power in cooling (min. - nom. - max.)
|
kW |
0,09 - 1,02 - 1,75 |
0,09 - 1,58 - 2,0 |
0,11 - 2,21 - 2,62
|
Absorbed power in heating (min. - nom. - max.)
|
kW
|
0,09 - 1,35 - 2,95
|
0,09 - 1,63 - 3,2
|
0,11 - 2,35 - 3,68
|
Starting current
|
A |
5,90 |
7,20 |
10,3
|
E.E.R. (cooling)
|
W/W |
4,12 |
3,29 |
3,21
|
C.O.P. (heating)
|
W/W |
4,44 |
4,11 |
3,62 |
Energy consumption / 500hrs
|
kWh |
675 |
815
|
1120 |
Energy classification
|
|
A/A
|
A/A
|
A/A |
Compressor type
|
|
Rotary |
Rotary
|
Rotary |
Sound pressure level @ 1 m (High) (C/H)
|
dB |
46 / 47 |
47/48
|
53/54
|
Dimensions (H x W x D)
|
mm |
578x790X300
|
578x790X300
|
830x900x330 |
Weight
|
kg |
39 |
39
|
62 |
Cooling pipes
|
inch |
1/4 - 1/2 |
1/4 - 1/2
|
1/4 - 5/8 |
Quantity of prefilled refrigerant
|
g |
1350 |
1350
|
1900 |
Quantity of additional refrigerant
|
g/m |
20 |
20
|
40
|
Number of prefilled meters
|
m |
15 |
15
|
15
|
Maximum length/heigth cooling pipe
|
m/m |
20/15 |
20/15
|
30/20 |
Minimum length cooling pipe
|
m |
3 |
3
|
3 |
Operating temperature in cooling
|
°C |
-10~43 |
-10~43 |
-10~43 |
Operating temperature in heating
|
°C |
-15~24 |
-15~24 |
-15~24 |
Power supply
|
|
AWYZ
|
AWYZ |
AOYZ |
Cable section between indoor & outdoor unit
|
mm²
|
4G 2,5
|
4G 2,5
|
4G 2,5 |
* Specifications and design are subject to changes for further improvement without notice.
|
* Cooling/Heating capacities are realised under the following conditions.
|
(Cooling) Indoor temp.:27°C D.B./19°C N.B. - Outdoor temp.:35°C D.B./24°C N.B.
|
(Heating) Indoor temp.:20°C D.B. - Outdoor temp.:7°C D.B./6°C N.B.
|
* I.U.=Indoor Unit / O.U.=Outdoor Unit
|