Izolator wejść oscyloskopów
Izolator wejść oscyloskopu. Zasilanie izolatora poprzez USB (izolatora nie może być zasilany że źródła zasilania oscyloskopu lub sygnału mierzonego)
Features and Benefits:
- Plug and play, oscilloscope option
- USB 5V power supply, power consumption less than 1 w, ease of use
- Single channel isolation voltage 1000 VRMS, channel segregation voltage 2000 VRMS
- Can be used to measure the total not to signal. Household 220 v ac signal; Three-phase ac electrical signals, etc
- Use this product to achieve common oscilloscope channel segregation, measured signal and the earth's isolation
Isolated Front End ISFE Siglent
Application:
1. Medical equipment maintenance
2. Industrial power source design
3. Motor power analysis
4. Floating ground differential signal analysis
Input voltage range |
-600Vpk~+600Vpk |
Voltage attenuation ratio |
about 200:1 |
Bandwidth |
≤1MHz |
Output voltage range |
-3Vpk~ +3Vpk |
Working voltage |
5V±5%, USB supply power |
Working current |
<200mA |
max isolated voltage to ground |
1000Vrms |
max isolated voltage between channels |
2000Vrms |
Input impedence |
10 MΩ |
Remark: DSO(with data recorder) + ISFE(isolated channel option) + PSA(power software analyzing) can be used as professional solution in strong current field.