FLUKE 319 New TRUE RMS Clamp Meter with backlight

Meters Features:

  1. Current sensing clamp
  2. Tactile barrier
  3. Rotary function switch
  4. Select ac or dc modes
  5. Hold button: freezes the display reading and releases the reading when pressed a second time.
  6. LCD
  7. Min Max button:when first pressed, the meter shows maximum input. With subsequent presses, the minimum and average inputs are shown. Hold the button for 2 seconds to exit minmmax mode. This function works in Current, Voltage, and Hz modes.
  8. Inrush button (319 only): press this button to enter inrush mode. Press it a second time to exit. Integration time is 100 ms.
  9. Volts/Ohm input terminal
  10. Common terminal
  11. Zero button; zeros the display for dc measurrement.
  12. backlight button: turns the backlight on and off. The Backlight stays on for 2minutes when there is no button switch interaction and then shuts off.
  13. Jaw release
  14. Alignment marks; to meet accurancy specifications the conductor must be aligned with the marks.

General Specifications:

Digital display: 6000 count resolution

Low battery Indication: Displays (an icon appear in LCD) when the batteries are below their required voltage

Power Source: 3 AAA IEC LR03 batteries

Clamp Opening Size: 1.45in (37mm)

Jaw Diameter: 1.45in (37mm)

Dimension (LxWxH): 6.39 inx 2.29in x1.20 in (162.4mm x 58.25mm x30.5mm) (exclude the clamp size)

Weight: approximately 13.5 oz (384g) (bateries included)

Electrical Specifications:

The accracy specification is defined as +/-(% reading +digits) at 23 ℃ +/- 5

 

Function (A ac): Range : 40.00A/600.0A/1000A

Resolution: 0.01A/0.1A/1A

Accuracy: 1.6% +/- 6digit (50-60HZ) [40A]

 

2.5 +/- 8 digit (60-500Hz) [40A]

1.5 % +/- 5 sigit (50-60 Hz) [600/1000A]

2.5 +/- 5 digit (60-500Hz) [600/1000A]

Crest factor add 2% into spec for CF>2: 3.0 Max@ 500A

2.5 Max@600A

1.4 M ax@1000A

AC response: RMS

Function (A dc): Range : 40.00A/600.0A/1000A

Resolution: 0.01A/0.1A/1A

Accuracy: 1.6% +/- 6 digit [40A]

1.5 % +/- 5 sigit [600/1000A]

Function (V ac): Range : 600.0V

Resolution: 0.1V

Accuracy: 1.5% +/- 5 digit (20-500Hz)

AC response: RMS

Function (V dc): Range : 600.0V

Resolution: 0.1V

Accuracy: 1% +/- 4 digit

Function (ohm): Range : 400.0Ω/4000Ω

Rresolution: 0.1Ω/1Ω

Accuracy: 1% +/- 5 digit

Function: )))) 30Ω

Function (Inrush): Integration time : 100 ms

Function (Hz): Range : 5.0 - 500.0 Hz

  Accuracy: 0.5% +/- 5 digit

Trigger Level: 10-100Hz 5A, 5- 10Hz, 100 - 500Hz ≧ 10A