Throughput per hour, native (uncompressed): |
(maximum configuration 4 drives) LTO Gen 1 (15 MB/sec) - 216.0 GB/hr LTO Gen 2 (30 MB/sec) - 432.0 GB/hr LTO Gen 3 (80 MB/sec) - 1152.0 GB/hr SDLT 320 (16 MB/sec) - 230.4 GB/hr SDLT 600 (36 MB/sec) - 518.4 GB/hr |
Audit time: |
<2 min |
Average cell to drive time: |
6.0 sec |
Capacity, native (uncompressed): |
(maximum configuration 40 cartridges) LTO Gen 1 (100 GB/cart) - 4.0 TB LTO Gen 2 (200 GB/cart) - 8.0 TB LTO Gen 3 (400 GB/cart) - 16.0 TB SDLT 320 (160 GB/cart) - 6.4 TB SDLT 600 (300 GB/cart) - 12.0 TB |
Number of cartridge slots: |
20, 40 |
Number of tape drives / types: |
1-4 LTO Gen 1, 2, 3, SDLT 320, SDLT 600 drives or a combination |
Cartridge access port (CAP): |
2-cartridge slot CAP |
Mean exchanges / swaps between failure (MEBF/MSBF): |
2,000,000 |
Mean time between failures (MTBF): |
360,000 hr (full operation) |
Mean time to repair (MTTR): |
<30 min |
Non-disruptive serviceability: |
Hot-swappable drives with power supply and fan, plus Ethernet and serial ports for diagnostics and reporting. |
Supported host platforms: |
UNIX, Linux, Windows, Novell NetWare |
Robotics control interfaces: |
LVD or HVD SCSI |
Any Cartridge Any Slot™ technology: |
Simultaneous non-partitioned support of multiple tape and media types |
Library Admin software: |
Advanced reporting monitoring and notification of the library (optional) |
Library Manager software: |
Remote management and true library sharing between applications within a network (optional) |
Framework Library Monitor software: |
Host-based, and over SCSI. Allows the library to be centrally viewable via a framework application. (i.e. Computer Associates Unicenter, Hewlett-Packard OpenView, Tivoli NetView) (optional) |
Library Status Tool software: |
Embedded software for remote monitoring and diagnostics of entire system |
SNMP: |
Embedded SNMP agent that enables remote reporting, monitoring and notification via standard Ethernet connection |
Digital vision system: |
Unique digital vision camera system performs continuous calibration and reads bar codes |
Operator panel: |
User-friendly configuration and diagnostic controls, status display and viewing window |
Automatic clean: |
Dedicated cleaning cartridge slot for tape drive cleaning by library or software command |
Automatic self discovery: |
Self-configures the drives, slots and CAP. Also identifies drive and media types |
Continuous automation calibration: |
No periodic maintenance or alignment required |
Height: |
17.5 in (44.5 cm) |
Depth: |
29.75 in (75.6 cm) |
Width: |
19.0 in (48.3 cm) |
Unit height: |
10u* of standard 19 inch rack space |
Weight: |
98.0 lb (44.45 kg) |
Temperature (operating): |
+50° to +104° F (+10° to +40° C) |
Temperature (non-operating): |
+50° to +104° F (+10° to +40° C ) |
Relative humidity (operating): |
20%–80% |
Relative humidity (non-operating): |
10%–95% |
Voltage: |
100–240 VAC @ 50–60 Hz single phase (auto-ranging) |
Library (operating maximum continuous - not peak): |
1.40 A @ 120 V, 0.75 A @ 240 V, 180 V or 0.18 KVA, 615 BTU/hr |
Optional internal FC/SCSI router: |
28 VA |
Drives: |
Drive power consumption varies. Refer to individual drive specifications |
Safety: |
CSA standard CAN/CSA-C22.2, no.950-95; UL listed to UL 1950, 3rd Edition; GS licensed to EN 60950, 2nd Edition, 1991 + A1, A2, A3, A4 Nemko, Semko, Demko, Finko certified to EN 60950, (1992) A1/A2/A3/A4/A11, EMKO-TSE (74-SEC) 207/94; CB test certified |
Emissions: |
FCC #47, part 15, subpart B, class A; VCCI class A European Union CE emissions standards AS/NZS 3548; 1996 (Australia, N.Z.); ICES-003 (Canada) |
Immunity: |
European Union CE immunity standards |